G. Remote Start/Stop Switch Connections
The control is supplied with a prewired Start/Stop Switch with a normally open "NO"
stop contact. Jumper J6 is factory set to the "NO" position.
For remote 3-wire Start/Stop Switch with a normally closed "NC" stop contact, connect
the switch as shown in Figure 7A, below. Set Jumper J6 to the "NC" position.
Figure 7A
Remote 3-Wire Start/Stop Switch
with Normally Closed Stop Contact
START
STOP
&KDQJHVWR:LULQJ6HFWLRQ,,,.RQ3DJH
K. Enable Connection
Wire the Enable contact to Terminals "EN1" and "EN2" of Terminal Block TB3 as
shown in Figure 10A, below.
The Enable is used to electronically start and stop the control. When the Enable
contact is closed, the control will accelerate to the Main Speed Potentiometer setting.
When the Enable contact is opened, the control will coast to stop.
Note: The contact must be isolated from the AC line and Jumper J7 must be removed.
Figure 10A
Enable Switch Connection
WARNING! Disconnect main power when making connections to the drive.
The following information and instructions are to be used as a supplement to the
KBPW-240D Installation and Operation Manual Rev. A (Part No. A40360). The manual
must be read and understood before attempting to operate this control.
The PC board has been upgraded to include provision for normally open or normally
closed stop contacts and to connect an Enable switch. The General Performance
Specifications have not changed.
Jumper J6 (Stop Switch type "NO" or "NC" Selection) and Jumper J7 (Enable
Selection) have been added. Enable terminals have been added to Terminal Block
TB3. Also, Figures 7A and 10A have been added.
&KDQJHVWR7DEOHRI&RQWHQWVRQ3DJHLL
Figure
Page
7A Remote 3-Wire Start/Stop Switch with Normally Closed Stop Contact ..................8
10A Enable Switch Connection .....................................................................................9
ENABLE SWITCH
Page 1 of 2 Page 2 of 2
KB Electronics, Inc.
(A42140) - Rev. A00 - 3/22/2005 - Z3570A00
Seitenansicht 0
1 2 3 4 5 6 ... 18 19

Inhaltsverzeichnis

Seite 1 - ENABLE SWITCH

.%3:',QVWDOODWLRQDQG2SHUDWLRQ0DQXDO5HY$6XSSOHPHQWDO,QIRUPDWLRQ&KDQJHVWR:LULQJ6HFWLRQ,,,*RQ3DJHG. Remote Start/Stop S

Seite 2 - MODEL KBPW-240D

operation (230 Volt AC line input with 90Volt DC SCR rated motor or 130 Volt DCPWM rated motor) set jumper J1 to“90V” position. However, in

Seite 3

G. Remote Start/Stop Switch Connections – The control is supplied with a prewiredStart/Stop switch mounted on the front cover. To

Seite 4

K. Enable Connections – The control can also be started and stopped with an Enable cir-cuit (close to start). See Figure 10. This circuit functions o

Seite 5

For motors of lower amper-age, set jumper J2 to the cor-responding position for themotor being used. SeeFigure 13 on page 9 andTable

Seite 6 - TABLE 1 – ELECTRICAL RATINGS

NTCL (Non-Timed Current Limit) – When jumper J3 is set to “NTCL” position, the con-trol will not go into “STOP” after it is in overload.Note: TCL trim

Seite 7 - Enlarged view of trimpots

The KBPW-240D is designed with a hingedcase so that when the front cover is open, allwiring stays intact. To open the cover, thefour sc

Seite 8 - PENTA-DRIVE

D. Minimum Speed (MIN) – Sets minimum speed of the motor. The MIN trimpot is factoryset for 0% speed. For a higher minimum speed setting, rotate the

Seite 9 - FIGURE 3 – POWER CONNECTION

(jumper J3 set to “TCL” position). The control can be reset by either setting the start/stopswitch to “START” position or by disconnecting and reconn

Seite 10

XI. LIMITED WARRANTYFor a period of 18 months from the date of original purchase, KB Electronics, Inc. will repairor replace, without charge, devices

Seite 11 - FIGURE 9 – INHIBIT CIRCUIT

RECONDITIONING THE BUS CAPACITORS If this drive has been in storage for over one year it is necessary to recondition the power supply bus capacitors.

Seite 12 - FIGURE 11 – DC TACH-GENERATOR

INSTALLATION AND OPERATING INSTRUCTIONSMODEL KBPW-240DKB Part No. 8401 (Black Case) • Part No. 8402 (White Case)NEMA 4X, IP-65PWM DC Motor Speed Contr

Seite 13 - TCL NTCL

TABLE OF CONTENTSSection Pagei. Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 14 - WITH ADDITION OF R

I. INTRODUCTIONThank you for purchasing the KBPW-240D. KB Electronics, Inc. is committed to providingtotal customer satisfaction by producing quality

Seite 15 - FIGURE 18 – RUN RELAY OUTPUT

Optional accessories include On/Off AC Line Switch, FWD-BRK-REV Switch, Run-Stop-JogSwitch, Signal Isolator, and Anti-Plug Reversing Module. Quick-co

Seite 16

D. Motor Current – Jumper J2 is factory set for 7.5 Amp motors. For lower current motors,set jumper J2 to the corresponding motor current as describe

Seite 17

CLYRGBSTOPONLED BOARDVIOLETORANGESTART/STOP SWITCHWHITEMAIN SPEEDPOTENTIOMETER J6BJ6AL2BL1BL1A L2AJ7BJ7A0.21.70.50.80.4AMPS0.33.57.55.02.5HL90V180VTTA

Seite 18 - XI. LIMITED WARRANTY

5BRKREVFWD0.357[9.07]  8.876[225.45]  8.226[208.94]  5.472[138.99]  5.886[149.50] %1009080706050403020100NEMA-4X / IP-

Seite 19

III. WIRING INSTRUCTIONSWarning! Read Safety Warning,on page 1, before using thiscontrol. Disconnect the AC line beforewiring.Note: T